نتایج جستجو برای: Electrochemical sensor

تعداد نتایج: 236696  

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه صنعتی اصفهان - دانشکده شیمی 1390

abstract venlafaxine, 1–[2–(dimethylamino)–1–(4–methoxyphenyl) ethyl]cyclohexanol hydrochloride is a novel non-tricyclic antidepressant. venlafaxine is a second generation antidepressant drug, has a neuropharmacologic profile distinct from that of existing antidepressants including tricyclic compounds, selective serotonin reuptake inhibitors and monoamine oxidase inhibitors. venlafaxine impart...

Journal: :iranian journal of pharmaceutical sciences 0
hossein hamzeiy bpharmacology and toxicology department, faculty of pharmacy, tabriz university of medical sciences, tabriz, iran mehdi saberian aresearch center for pharmaceutical nanotechnology, bpharmacology and toxicology department, faculty of pharmacy, tabriz university of medical sciences, tabriz, iran davoud asgaria research center for pharmaceutical nanotechnology, yadollah omidi research center for pharmaceutical nanotechnology,

electrochemical aptamer-based sensors attract a lot of interest as useful methods because of their low cost, accuracy, sensitivity, and simplicity. an electro-active redox molecule comprises the main part of the electrochemical-based sensors. ferrocene is one of the most popular redox molecule used in biosensor fabrication. but, instability of ferrocenium ion in strong nucleophilic reagents and...

Ali Akbar Moghadamnia Atieh Zabihollahpoor, Ghasem Najafpour-Darzi Mostafa Rahimnejad,

Herein, gold nanoparticle had been successfully synthesized through a simple, inexpensive and clean electrochemical technique. Gold nanoparticles were directly deposited on the electrode surface using an electrochemical strategy. Then, the electrochemical deposition parameters (such as applied potential and deposition time) were optimized. 1.1 V and 250 s were applied as the optimal electrodepo...

A novel electrochemical sensor was proposed for the determination of amitriptyline based on the copper oxide (CuO) nanoparticles modified graphite screen-printed electrode. CuO nanoparticles were used to enhance the surface area of the electrode and then improve the sensitivity of the electrochemical sensor. Amitriptyline electrochemical response characteristics of the modified electrode in a p...

A novel electrochemical sensor was proposed for the determination of amitriptyline based on the copper oxide (CuO) nanoparticles modified graphite screen-printed electrode. CuO nanoparticles were used to enhance the surface area of the electrode and then improve the sensitivity of the electrochemical sensor. Amitriptyline electrochemical response characteristics of the modified electrode in a p...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه ارومیه - دانشکده علوم 1386

چکیده ندارد.

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه رازی - دانشکده علوم 1389

fluorescence chemical sensors for the highly sensitive and selective determination of pb2+ , hg2+, co2+ and fe3+ ions in aqueous solutions are described. the ion sensing system was prepared by incorporating lipophilic ligand (l) as a neutral ion-selective fluoroionophore in the plasticized pvc membrane containing sodium tetraphenylborate or potasium tetrakis (p-chlorophenyl) borate as a liphoph...

Journal: :journal of nanostructures 0
mohammad mazloum-ardakani department of chemistry, faculty of science, yazd university, yazd, 89195-741, iran fatemeh farbod department of chemistry, faculty of science, yazd university, yazd, 89195-741, iran laleh hosseinzadeh department of chemistry, faculty of science, yazd university, yazd, 89195-741, iran

the combination of graphene (gr) and nickel oxide nanoparticles (nio nps) yields nanostructured electrochemical sensor formed a novel kind of structurally uniform and electrocatalytic activity material. in cyclic voltammetry (cv) studies, in the presence of ep, nio/gr composite modified electrode shows a significantly higher current response for ep oxidation. based on differential pulse voltamm...

Davoud Asgaria Hossein Hamzeiy, Mehdi Saberian Yadollah Omidi

    Electrochemical aptamer-based sensors attract a lot of interest as useful methods because of their low cost, accuracy, sensitivity, and simplicity. An electro-active redox molecule comprises the main part of the electrochemical-based sensors. Ferrocene is one of the most popular redox molecule used in biosensor fabrication. But, instability of ferrocenium ion in strong nucleophilic reagents...

Journal: :physical chemistry and electrochemistry 0
elham eslami department of chemistry, kazerun branch, islamic azad university, kazerun, iran fatemeh farjam department of chemistry, marvdasht branch, islamic azad university, marvdasht, iran

we used an effective electrochemical sensor for the determination of imipramine at ph 7.2 using a carbon nanocomposite electrode. the electrode has been designed by incorporation of montmorillonite nanoclay into the carbon ionic liquid electrode. the high sensitivity of 1.714 μa (μm)-1, two linear calibration ranges of 0.1–2 μm and 2-40 μm, and detection limit of 19 nm were achieved. the relati...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید